Technical Parameters:
Ambient temperature -40 ~ 65 ℃ (+80 ℃ conditions, up to two hours)
Switch SPDT switch
Contact load AC: AC1: 16A, 400V AC3: 16A, 400V AC15: 10A, 400V
The maximum opening current (L.R.): 112A, 400V
DC: DC13: 12W, 220V controllable current
Wire Size Solid / Cable 075-2.5mm2 Soft / Without Metal Sleeve 0.7-2.5 mm2 Soft / With Metal Cover 0.5-1.5 mm2
Tightening torque Max. 2NM Rated impulse voltage 4kV Pollution degree 3 Short-circuit protection, fuse 10Amp
Insulation 400V IP 30/44
Wire connection
The wire interface can be used for wires with a diameter of 6 to 14 mm
Cable connection
The cable interface can be used for cables with diameters from 6 to 14 mm. A Pg13.5 spiral cable entry can be used for cables with a diameter of 6-14 mm. A cable with a diameter of 8-16 mm can use the spiral cable entry of the Pg16
shell
When the controller is mounted on a flat surface or bracket, the enclosure protection class IP30 (IEC529) can be achieved and the bracket must be secured so that all holes are covered
KP pressure controls are for use in refrigeration and air conditioning systems to give protection against excessively low suction pressure or excessively high discharge pressure. The controls are also used for starting ans stopping refrigeration compressors and fans on air- cooled condensers. KP pressure controls are available in IP 30 and IP 44 enclosures.
Product Features
1,KP Dual Pressure Controls are available in versions for regulation of high pressure on both left and right side or regulation of low pressure on left and high pressure on right side (versions with LP signal or LP+HP signals). Enclosure rating IP30 or IP44.
2,Ultra-short bounce time thanks to snap-action function (reduces wear to a minimum and increases reliability)
3,Manual trip function (electrical contact function can be tested without the use of tools)
4,Vibration and shock resistant
5,Compact design
6,Fully welded bellows element
7,High reliability both electrically and mechanically
Pressure controls are pressure-activated switches, with a basic function to make or break an electrical circuit which in tur controls a solenoid coil, a contactor or some other functioning part of the system.
The set point at which a control closes a contact and makes a circuit is called the cut-in point.
The point at which the control opens the switch and breaks the circuit is called the cut-out point.
The difference between the cut-in and cut-out point is known as the differential.
1. KP pressure controls are for use in refrigeration and air conditioning systems to give protection
Against excessively low suction pressure or excessively high discharge pressure.
2. KP pressure controls are also used for starting and stopping refrigeration compressors and fans
On air-cooled condensers.
3. KP pressure controls are fitted with a single-pole double-throw (SPDT) switch. The position of the
Switch is determined by the pressure control setting and the pressure at the connector.
Filling | Model No. | Type | Setting range | ΔT | reset | Max type | Capillary length m |
Code No. | |
℃ | setting range selected as the lowest value | setting range selected as the highest value | Temp ℃ | ||||||
Steam Filling | KP 61 | A | -30~15 | 5.5~23 | 1.5~7 | Auto | 120 | 2 | 060L110066 |
KP 61 | A | -30~15 | 5.5~23 | 1.5~7 | 120 | 5 | 060L110166 | ||
KP 61 | B | -30~13 | 4.5~23 | 1.2~7 | 120 | 2 | 060L110266 | ||
KP 63 | A | -50~-10 | 10.0~70 | 2.7~8 | 120 | 2 | 060L110766 | ||
KP 63 | B | -50~-10 | 10.0~70 | 2.7~8 | 120 | 2 | 060L110866 | ||
Adsorption Filling | KP 75 | F | 0~35 | 3.5~16 | 2.5~12 | 110 | 2 | 060L112066 | |
KP 77 | E3 | 20~60 | 3.5~10 | 3.5~10 | 130 | 2 | 060L112166 | ||
KP 79 | E3 | 50~100 | 5.0~15 | 5.0~15 | 150 | 2 | 060L112666 | ||
KP 81 | E3 | 80~150 | 7.0~20 | 7.0~20 | 200 | 2 | 06L112566 |
Code | Type |
KP | |
060-110191 | Pressure control KP 1 |
060-114166 | |
060-115266 | Pressure control KP 1A |
060-111266 | Pressure control KP 1 |
060-111166 | |
060-111066 | |
060-110966 | |
060-112066 | Pressure control KP 2 |
060-112366 | |
060-117191 | Pressure control KP 5 |
060-117366 | |
060-117766 | |
060-117866 | |
060-117966 | |
060-118066 | |
060-519066 | Pressure control KP 6 |
060-519166 | |
060-124166 | Pressure control KP 15 |
060-124366 | |
060-124566 | |
060-125466 | |
060-115466 | |
060-126166 | |
060-126466 | |
060-126566 | |
060-128466 | |
060-129966 | |
060-122066 | |
060-001066 | |
060-116066 | Pressure control KP 1A |
060-116166 | |
060-116266 | |
060-115366 | Pressure control KP 5A |
060-123066 | |
060-123166 | |
060-129366 | Pressure control KP 15A |
060-129466 | |
060-129566 | |
060-129666 | |
060-128366 | |
060-119066 | Pressure control KP 7W |
060-120366 | |
060-119166 | Pressure control KP 7B |
060-119266 | Pressure control KP 7S |
060-120066 | Pressure control KP 7BS |
060-127566 | Pressure control KP 17W |
060-127666 | |
060-126766 | |
060-126866 | Pressure control KP 17B |
060-127466 | |
060-120566 | Pressure control KP 7 ABS |
060-005766 | Welded connections |
060-007866 | Capillary |
060-008266 | Capillary |
060-014166 | Adapter |
060-033066 | Spare parts |
060-035066 |
Item No. | pressure | Low pressure | High pressure | Reset | Contact System | Product code | |||||
Adjust range | Differential pressure | Adjust range | Differential pressure | Adjust range | Differential pressure | 1/4in | 1/4in | 6mm | |||
(bar) | (bar) | (bar) | (bar) | (bar) | (bar) | 6mm | ODF | ODF | |||
flare | solder | solder | |||||||||
KP1 | Low | -0.2-7.5 | 0.7-4.0 | Auto | SPDT | 060-1101 | 060-1112 | 060-1110 | |||
KP1 | Low | -0.9-7 | Fixed 0.7 | Manual | 060-1103 | 060-1111 | 060-1109 | ||||
KP2 | Low | -0.2-5 | 0.4-1.5 | Auto | 060-1120 | 060-1123 | |||||
KP5 | High | 8-32 | 1.8-6.0 | Auto | 060-1171 | 060-1179 | 060-1177 | ||||
KP5 | high | 8-32 | Fixed 3 | Auto | Manual | 060-1173 | 060-1180 | 060-1178 | |||
KP15 | Dual | -0.2-7.5 | 0.7-4.0 | 8-32 | Fixed 4 | Auto | Auto | SPDT+ | 060-1241 | 060-1254 | |
KP15 | Dual | -0.2-7.5 | 0.7-4.0 | 8-32 | Fixed 4 | Manual | Low | 060-1243 | |||
KP15 | Dual | -0.9-7 | Fixed 0.7 | 8-32 | Fixed 4 | Manual | Manual | signal | 060-1245 | ||
KP15 | Dual | -0.2-7.5 | 0.7-4.0 | 8-32 | Fixed 4 | Auto | Auto | SPDT+ | 060-1265 | 060-1299 | |
Low/high | |||||||||||
KP15 | Dual | -0.2-7.5 | 0.7-4.0 | 8-32 | Fixed 4 | Auto | Manual | signal | 060-1264 | 060-1284 | |
KP35 | Low | -0.2-7.5 | 0.7-4.0 | Auto | SPDT | 060-1133 G1/4 | |||||
KP36 | Low | 2 -14 | 0.7-4.0 | Auto | 060-1108 G1/4 | ||||||
KP38 | High | 8-32 | 1.8-6.0 | Auto | 060-5081 G1/4 |
Pressure controls | |
Part Number | Description |
Dual Pressure Controls | |
060-1241 | PRESSURE CONT. DUAL |
060-1243 | PRESSURE CONT. DUAL (M/R ON HP) |
060-1245 | KP15 HP/LP CONT M/R-LP M/R-HP |
060-1265 | PRESSURE CONT DUAL |
060-1264 | PRESSURE CONT. DUAL |
060-1154 | PRESSURE CONT. DUAL (UNIV.) |
060-1220 | KP15 HP/LP CONT UNI-RESET |
060-1254 | KP15S HP/LP CONTROL A/R |
MG00140 | KP15S HP/LP CONT A/R-LP A/R-HP |
060-1284 | PRSSURE CONT DUAL |
060-1199 | PRESSURE CONT DUAL |
060-0007 | PRESSURE CONT. DUAL |
high Pressure Controls | |
060-1171 | PRESSURE CONT. HP AUTO |
060-1173 | PRESSURE HIGH MANUAL |
060-1174 | PRESSURE CONTROL HP |
Low Pressure Controls | |
060-1101 | PRESSURE CONT. LP AUTO |
060-1103 | PRESS CONT LP FIXED DIFF |
060-1120 | KP2 LP CONTROL A/R |
060-1160 | R717 PRESSURE CONTROL KP1A |
060-1105 | PRESSURE CONT. LP |
ammonia Controls | |
060-1161 | KP1A LP CONTROL M/R NH3 |
060-1230 | KP5A HP CONTROL A/R NH3 |
060-1294 | KP15A HP/LP CONT A/R M/R NH3 |